Sent data could not be applied onto this device

Symptoms

When saving a device an error occures saying: "Sent data could not be applied onto this device", see also the example below:

image.png

Affected CoCoS version(s)

 - CoCoS v5.1.0

Solved in CoCoS version:

Not yet solved

Details

When saving a device, the error "Sent data could not be applied onto this device" is displayed. When opening the logMessage by clicking the link "Click here for more details", the service info/comments of the message give errors about fields like "intercomDialPlanParam006Name", "intercomDialPlanParam006Method",, "intercomDialPlanParam006Value", "intercomDialPlanParam006IdTag", "intercomDialPlanParam007Name", "intercomDialPlanParam007Method",, "intercomDialPlanParam007Value", "intercomDialPlanParam007IdTag", "intercomDialPlanParam008Name" and so on. See also the example below:

image.png

Application

This issue happened when an "invalid" amount of "intercomDialPlanParameters" was configured.

Solution / Resolution / How To

Navigate to "System" -> "Configuration" to get to the list of configuration variables for the system.

image.png

Search for the configuration variable dialPlanParameterLimit

image.png

Make sure the value is set to 20 end hit [ Enter ] to save the value.

image.png

After updating the configuration variable, it should be possible to save devices again.